FTTH fiber-to-the-home solutions
Optical communication component solutions

Control And Protection Specialist Onsite Commissioning

Browse technical resources about optical communication components, fiber technology, and network solutions.

  • Network patch panel surge protection module

    Network patch panel surge protection module

    The patch panels are available as versions with the new surge protection and shield current monitoring functions. The new DIN rail devices now also feature Push-in, IDC, or screw connection, in addition to the traditional RJ45 connection. Available in wall mount cases for 4 or 8 channels, and 1U rack mount enclosures for up to 24 channels, these systems use state-of-the-art circuitry for best-in-breed surge. DITEK Surge Protection is your first line of defense for Video Surveillance, Fire, Networking, Communications, Intrusion Detection, Access Control and AC Power systems. Featuring 24 independent ports, this device provides uncompromising protection for enterprise-level Ethernet. The PLx-CAT6 are surge protection devices in 19" format and offer protection against lightning and surge voltages for sensitive interfaces connected in a Gigabit Ethernet network. The protection circuit consists of a highly efficient combination of 3-pole gas arresters and low-capacitance diodes. Rack-mount indoor panel supports up to 10 GbE, PoE++, and 20kA surge discharge per port. Impulse Spark-Over Voltage Max.

    [PDF Version]
  • Relay protection distribution network cascade busbar

    Relay protection distribution network cascade busbar

    Literature review has shown that small distribution substations used for medium voltage make use of overcurrent relays to provide busbar protection and large substations make use of differential protection schemes. This technical article explains a busbar theory at the distribution. These types of protection are typically applied on distribution busbars, where fault current magnitudes are lower and speed is generally less critical than with transmission busbars. Differential protection provides high speed fault-clearing necessary for critical busbars such as transmission. A busbar is a strip or bar of copper, brass or aluminum that conducts electricity within a switchboard, a substation or a battery bank. Its purpose is to conduct a substantial current of electricity. In the case of a fault, current on the busbar becomes high, resulting to mechanical destruction which would affect all feeders. However, due to impedance grounding, the single-phase-to-ground short circuit current have small.

    [PDF Version]
  • The lightning protection wire is located above the optical cable

    The lightning protection wire is located above the optical cable

    A static shield or optical ground wire (OPGW) protects power and data transmission lines from lightning strikes. As part of the lightning protection ground wire, it MUST be able to withstand lightning. An optical ground wire (also known as an OPGW or, in the IEEE standard, an optical fiber composite overhead ground wire) is a type of cable that is used in overhead power lines. Such cable combines the functions of grounding and telecommunications. ● High-Speed Communication: Modern utility exchange demands benefit from the optical.


  • Can aluminum cable trays be used for fire protection

    Can aluminum cable trays be used for fire protection

    In the event of a fire, aluminum trays can quickly soften and melt, allowing flames to spread. Fire-resistant cable trays that support electrical and communication cables in hospitals must be made of fire-resistant materials to ensure uninterrupted operations during emergencies. Commercial buildings. Select tray materials and finishes that match the hazard: hot‑dip galvanised steel or stainless for durability; aluminium for lighter loads; FRP for corrosive plants. Use fire barriers, covers, and dividers to. “Can I use aluminum cable trays near hydrogen gas? What stops them from causing explosions?” If you manage petrochemical plants or energy facilities, you've asked this.

    [PDF Version]
  • Upgraded version of relay protection cabinet

    Upgraded version of relay protection cabinet

    Find top-rated relay protection cabinets with microprocessor-based protection, SCADA integration, and IEC 61850 protocol. Click to discover reliable, customizable solutions for your power systems. These cabinets house the intelligent protective relays that act as the nervous system of modern electrical networks. SEL direct-replacement assemblies are complete, preassembled retrofit kits designed to match the form factor, terminal layout, and functionality of. and upgrade services allows modifying the product throughout the entire product life cycle. A thorough assessment identifies gaps and informs a prioritized compliance plan aligned with current codes.

    [PDF Version]
  • Six-phase Microprocessor-based Relay Protection Tester

    Six-phase Microprocessor-based Relay Protection Tester

    TEST-630 six phase microcomputer protection relay test kit is a smart relay test equipment which offers all the characteristics and functions needed for protective relay testing, in a manual or automatic mode, designed for using on site or in the laboratory. All types of protection relays, including electro-mechanical, solid state and modern microprocessor based, can be easily tested with our automatic relay testing software. JBC-806tester can simultaneously outputstandard six-phase current and six-phase voltage with 30A/phase current and 125V/phase voltage.


  • CAT Relay Protection

    CAT Relay Protection

    To assist in protecting the generator set from the overcurrent event, the Cat Integrated Voltage Regulator (IVR) Excitation Module employs a built-in over-excitation protection. This protection strategy, illu.


  • Digital Relay Protection System

    Digital Relay Protection System

    The digital protective relay is a protective relay that uses a microprocessor to analyze power system voltages, currents or other process quantities for the purpose of detection of faults in an electric power system or industrial process system. Experience the benchmark in grid protection, automation, and monitoring! SIPROTEC 5, built on extensive field experience, offers comprehensive functionalities and device types for modern electrical energy systems. Its modular design and powerful DIGSI 5 engineering tool provide tailored solutions. In utility and industrial electric power transmission and distribution systems, a numerical relay is a computer-based system with software-based protection algorithms for the detection of electrical faults. By monitoring key electrical parameters, these devices ensure the safety and continuity of power generation and. Microprocessor-based Operation: Digital relays use microprocessors to analyze incoming electrical signals and determine the appropriate switching action. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions.

    [PDF Version]
  • Relay protection devices 103 and 133

    Relay protection devices 103 and 133

    In and, ANSI Device Numbers can be used to identify equipment and devices in a system such as,, or. The device numbers are enumerated in / Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations. Many of these devices protect electrical systems and individual system components from damage whe.


More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +27 82 415 6793
Address Unit 7, Innovation Park, 34 Electron Road, Kempton Park, 1620, South Africa

Send an Inquiry