FTTH fiber-to-the-home solutions
Optical communication component solutions

Effect Of Grit Size On Airborne Particle Concentration

Browse technical resources about optical communication components, fiber technology, and network solutions.

  • What size transformer requires relay protection

    What size transformer requires relay protection

    Fuses may adequately protect small transformers, but larger ones require overcurrent protection using a relay and CB, as fuses do not have the required fault breaking capacity. Under normal conditions, these currents balance. If the difference exceeds a threshold, it indicates an internal fault, and the relay trips the circuit breaker. It is the most sensitive protection for internal winding. Transformer protection is crucial as transformers are one of the most critical and expensive components of any distribution system. Setting procedures are only discussed in a general nature in the material to follow.


  • What size bolt should be used for cable trays

    What size bolt should be used for cable trays

    The cable trays are fastened to the cantilever brackets with 2 mushroom head bolts (FLM 6X12/FLM 6X16 F). The exceptions to this are vertical bends. The cable support lengths and fittings can basically be designed as cable trays, cable ladders or mesh cable trays, in which cables are routed. Fittings can, on the one hand, be used for horizontal or vertical changing of the routing direction or, on the other, to change the height or width of the. maintain spacing or to keep cables in place when the tray is ect the minimum bend ra-dius for cables as they exit the bottom of the cable tray. TKS pendant brackets up to a length of 900 mm and TKS 150 to TKS 350 brackets or TKS 100 to TKS 300 brackets with KAWG 12 bracket. The screw-on cable tray systems fulfil the requirements of “IEC 61537:2006 – Cable management ‒ Cable tray systems and cable ladder systems” for the low voltage area.

    [PDF Version]
  • Controlling the size of the small busbar

    Controlling the size of the small busbar

    The smallest passing busbar size will be selected automatically. The busbar sizing calculator determines the required busbar dimensions based on the continuous current rating, short circuit withstand, and thermal limits for switchgear assemblies. 2 A/mm² for conservative / high‑temperature designs. You can select, say, 2×50×6 mm. Bus bars are the essential components in the electrical distribution systems (EDB) serving as primary conductors that carry current between 1). The current rating is calculated from the conductor. Busbar Length (m):Length of the busbar for voltage drop and power loss calculations. Always verify with specific standards and manufacturer data. Selecting material: Select Copper or Aluminum from the.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +27 82 415 6793
Address Unit 7, Innovation Park, 34 Electron Road, Kempton Park, 1620, South Africa

Send an Inquiry